Researchers Find No Increased Risk of Death with Drug-Coated Devices Used for Lower Extremity Revascularization

Terri Janos tjanos@bilh.org

MAY 17, 2021

Boston – Peripheral artery disease (PAD), or blockages in the arteries outside of the heart, affects more than 200 million people worldwide and 12.5 million people in the United States. Patients with this circulatory disorder may develop severe leg pain or unhealing wounds that require a minimally invasive revascularization procedure to open the blood vessels to improve blood flow.

For nearly a decade, proceduralists and surgeons have depended on devices coated with a drug called paclitaxel — which reduces the need for another procedure by up to 50 percent — during procedures to open the arteries of the leg. However, in the wake of a 2018 study that found a potential link between these drug-coated peripheral devices and death after two years post procedure, the FDA restricted the use of these devices for the treatment of PAD out of an abundance of caution.

At the behest of the FDA, cardiologists Eric Secemsky, MD, and Robert Yeh, MD, both of the Richard A. and Susan F. Smith Center for Outcomes Research in Cardiology at Beth Israel Deaconess Medical Center (BIDMC), designed the Safety Assessment of Femoropopliteal Endovascular Treatment With Paclitaxel-coated Devices (SAFE-PAD) study to provide the information necessary to make scientifically-sound regulatory decisions about the safety of these devices. Using claims data from the Centers for Medicare & Medicaid Services (CMS), the researchers evaluated survival following treatment with these drug-coated devices in more than 160,000 leg artery revascularization procedures conducted between 2015 and 2018.

The team found no statistically significant difference in mortality between patients treated with drug-coated devices and non-drug-coated devices. The report was presented as a late-breaking study at the American College of Cardiology's Scientific Sessions May 16 and published simultaneously in JAMA Internal Medicine.

"Our study of Medicare beneficiaries includes more than 160,000 patients, including more than 30,000 patients with survival data extending past four years, making it one of the largest and most comprehensive evaluations of the safety of drug-coated devices to be published since the initial analysis," said Secemsky, Director of Vascular Intervention at BIDMC and Assistant Professor of Medicine at Harvard Medical School. "Although the 2018 findings raised concerns about the safety of these drug-coated devices, there were many issues with that analysis — including the study's small size and a lack of complete patient follow-up."

Secemsky and colleagues' study included Medicare patients treated with either a drug-coated or non-drug coated peripheral device between 2015-2018 at nearly 3000 hospitals across the United States. Deaths were evaluated through May 2020, and after accounting for any differences in demographics and co-morbidities between the two groups, the investigators found no evidence that drug-coated devices were associated with higher mortality rates through an average 2.7 years of follow-up, with some patients having follow-up through 5 years.

"We used a number of novel statistical methods to assure these results were accurate, and found consistent results across a number of different patient groups — including among those of lower overall risk, those with more severe disease, and those treated in outpatient centers," Secemsky said. "We've provided these results to the FDA to make decisions on whether to continue to restrict these drug-coated devices to only those at high risk of needing another leg procedure, or to return to the previous indications where these were used without restriction."

The current publication is the first report of seven planned biannual reports as part of the SAFE-PAD study, which was designed to continue until all patients in the study had follow-up exceeding 5 years. As such, Secemsky and colleagues will continue to analyze these Medicare beneficiaries and update their findings until this study completes in late 2023.

"The SAFE PAD study is a model example for collaboration between industry, academia and the FDA to carry out rigorously designed real world studies to evaluate important medical device safety signals," said Yeh, Director of the Richard A. and Susan F. Smith Center for Outcomes Research in Cardiology at BIDMC and Katz-Silver Family Associate Professor of Medicine Harvard Medical School. "We believe that applying stringent scientific standards to observational studies can create greater confidence in validity of these 'big data' approaches to the evaluation of medical therapies."

Co-authors included Changyu Shen, PhD, and Marc Schermerhorn, MD, of BIDMC.

Funding for the study was provided by a multi-industry consortium, including BD, Boston Scientific, Cook Medical, Medtronic, and Philips. Secemsky receives funding the National Heart, Lung, and Blood Institute (grant K23HL150290) and Harvard Medical School's Shore Faculty Development Award. Yeh receives funding from the National Heart, Lung, and Blood Institute (grant R01HL136708) and the Richard A. and Susan F. Smith Center for Outcomes Research in Cardiology.

Secemsky reported receiving grants from Philips, Medtronic, Boston Scientific, Cook Medical, and BD during the conduct of the study; and receiving grants from AstraZeneca, CSI, and Laminate Medical and personal fees from Philips, Medtronic, Boston Scientific, Cook Medical, BD, CSI, Janssen, VentureMed, Abbott, Bayer, and Inari Medical outside the submitted work. Schermerhorn reported receiving personal fees from Abbott, Cook Medical, Endologix, Medtronic, Philips, and Silk Road Medical outside the submitted work and participating in a scientific advisory board meeting without pay for Medtronic and Philips. Yeh reported receiving grants from BD Bard, Boston Scientific, Cook Medical, Medtronic, and Philips during the conduct of the study; and receiving personal fees from Boston Scientific, Medtronic, Shockwave Medical, and Zoll Medical outside the submitted work. No other disclosures were reported.

About Beth Israel Deaconess Medical Center

Beth Israel Deaconess Medical Center is a leading academic medical center, where extraordinary care is supported by high-quality education and research. BIDMC is a teaching affiliate of Harvard Medical School, and consistently ranks as a national leader among independent hospitals in National Institutes of Health funding. BIDMC is the official hospital of the Boston Red Sox.

Beth Israel Deaconess Medical Center is a part of Beth Israel Lahey Health, a health care system that brings together academic medical centers and teaching hospitals, community and specialty hospitals, more than 4,700 physicians and 39,000 employees in a shared mission to expand access to great care and advance the science and practice of medicine through groundbreaking research and education.